The Lever Actuator is a combination piston actuator and lever mechanism. These actuators are available in piston diameters of 6” and 8” with a maximum lever travel of 12”. Force produced is a function of the supply pressure which may be varied from 20 to 100 PSI (137 to 690 kPa) and the lever take-off position.
The actuator assembly is completely enclosed to protect all moving parts from corrosive atmospheres and adverse weather conditions. All exterior parts are coated with a corrosion-resistant paint.
Materials of Construction:
- Cylinder: Aluminum
- Piston: Aluminum
- Stem: 303 Stainless Steel
- Lipseals: Buna “N”
- Yoke and Base: One Piece Ductile Iron
- Lever: Steel
- Fulcrum Arm: Steel
- Lever and Fulcrum Pins: Steel
GB52SC (1)
- Piston Diameter: 6”
- Effective Area: 28.5 sq. in. (183.37 CM2)
- Air Consumption w/Positioner:
- Static: 0.30 SCFM (0.008 m3/min) at 40 PSI (275 kPa) supply
- Dynamic: 5.0 SCFM (0.142 m3/min) (max) at 100 PSI (690 kPa) supply
- Positioner: Suitable for all standard instrument air signals; direct or reverse acting, top or bottom loading (2)
- Standard Accessories: Integrally piped cushion-loading regulator and gauge (for units with positioners only)
- Approximate Shipping Weight: 30 lbs. (14 Kg)
GB53SC (1)
- Piston Diameter: 8”
- Effective Area: 50 sq. in. (322.58 CM2)
- Air Consumption w/Positioner:
- Static: 0.30 SCFM (0.008 m3/min) at 40 PSI (275 kPa) supply
- Dynamic: 5.0 SCFM (0.142 m3/min) (max) at 100 PSI (690 kPa) supply
- Positioner: Suitable for all standard instrument air signals; direct or reverse acting, top or bottom loading (2)
- Standard Accessories: Integrally piped cushion-loading regulator and gauge (for units with positioners only)
- Approximate Shipping Weight: 40 lbs. (18 Kg)
NOTES:
1) For catalog number make-up, refer to Control Engineering Data Sheets.
(A) Lever type actuators utilize clevis and fulcrum with 8 take-off positions. Lower stem guide on base assures constant alignment.
(B) Lever Actuator mounting is base type with four 1/2” holes on a 3-3/4” bolt circle.
(C) Maximum lever travel is 12”
2) For proper positioner selection, refer to positioner data sheets.