The GT_8 series electronic transducer is available with current inputs of 4-20 or 10-50 mA DC. Electrical connections are made through a 1/2” conduit connection and a terminal strip on the circuit board. These units are available with output signals of 3-15, 3-27, or 6-30 PSIG (21-103, 21-186, or 41-207 kPa), and are available in low volume or air relay equipped configurations.
Typical applications for these units include valve actuators and control room applications.
- Input Range: 4-20 mA DC | 10-50 mA DC
- Nominal Input Impedance: 145 ohms | 60 ohms
- Linearity: ± 1.5%
- Temperature Effect: 0.2%FS/10°F (-12°C) change for a 2°F/minute rate of change (2)
- Ambient Temperature Range: 0° to +150°F (-18° to +66°C)
- Approx. Shipping Weight: 7 lbs. (0.77 Kg)